진공로용 초고온 온도센서

진공로 용 S, R, B, C type Thermocouple (PJFC-Plug/Jack ) and Support Tube

DaiL IBC 2011. 8. 15. 16:06

 

High Temperature Thermocouple Assemblies

Operating Temperatures Up to 4200˚F (2315˚C)

 

for Vacuum Furnace

 

Thermocouple Assemblies with
PJFC-Plug/Jack Termination and Support Tube

 

Plug & Jack Assembly
An adjustable support tube offers flexibility for immersion adjustment while
protecting the sheath from potential damage during installation. The rigid, thick
wall offers additional support when penetrating the vessel/furnace wall.
Standard polarized plug and jack termination for use with all calibration types.
Plug and jack assemblies are made from molded glass filled thermoset
compounds and are designed to operate in temperatures
to 300˚ F (150˚ C). Polarity identification marks are
molded in the bodies for installation assistance.

 

SUPPORT TUBE DATA

Thermocouple

Diameter “A”

.Support Tube

Diameter “B”

Code

Fitting Length

.125"

.312"

C

1.12"

.187"

.312"

C

1.12"

.250"

.375"

D

1.50"

.375"

.500"

F

2.00"

 

 

Progressive Description Example:

C24-MO18-AL-U-PJFC - S 1 A V C 4 - 12.50"

 

 

Notes:
• .125" diameter sheath is available with 30 gauge wire only.
• Alumina sheath is not available in .125" diameter.
• Molybdenum, Tantalum and Tungsten are not available in .375" diameter.
• Lava sealant not recommended for high vacuum.
• Support tube materials: 316SS body and tube, 303SS cap and follower.
• Support tube assembly torque values, see page 14;
S1=MPG Series, S2=PG2 Series, S4=PG4 Series.

 

* Select sealant material:
L = Lava-up to 1600º F (870º C)
G = Grafoil-up to 925º F (495º C)
V = Viton -up to 450º F (232º C)

 

Conax Buffalo Technologies 는
Conax Technologies 의 옛 명칭입니다.
 
한국 총판 (주)다일아이비씨